Hanna-instruments HI 4011 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI 4011. Hanna Instruments HI 4011 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
HI 4011HI 4011
HI 4011HI 4011
HI 4011
HI 4111HI 4111
HI 4111HI 4111
HI 4111
Iodide Ion
Selective Electrode
Instruction Manual
Half-cell
Combination
IODIDE
HI 4011
HI 4111
IODIDE
COMBINATION
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Combination

1HI 4011HI 4011HI 4011HI 4011HI 4011HI 4111HI 4111HI 4111HI 4111HI 4111Iodide IonSelective ElectrodeInstruction Manual Half-cell CombinationIODI

Page 2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Page 3

11• If the membrane is damaged, the response becomesextremely sluggish, or the slope of the electrode hasdecreased significantly, and procedures above

Page 4 - Membrane

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards / solution.Standards

Page 5

13XII. XII. XII. XII. XII. Other Measurement TOther Measurement TOther Measurement TOther Measurement TOther Measurement Techniquesechniquesechniquese

Page 6

14An iodide electrode may be used as an indicator to followthe progress and detect the endpoint of a titration of iodidecontaining samples with silver

Page 7

15XVXVXVXVXV. . . . . Conversion TConversion TConversion TConversion TConversion TablesablesablesablesablesFor IFor IFor IFor IFor I-----Multiply

Page 8 - Deionized

16MAN4111 02/07R1 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warran

Page 9 - COMBINATION

2HI 4011 Iodide Half-cellHI 4011 Iodide Half-cellHI 4011 Iodide Half-cellHI 4011 Iodide Half-cellHI 4011 Iodide Half-cellHI 4111 Iodide Combination El

Page 10 - and place against damaged

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4011 or HI 4111 I

Page 11

4IV. IV. IV. IV. IV. Design elements of the HI 4011and HI 4111Design elements of the HI 4011and HI 4111Design elements of the HI 4011and HI 4111D

Page 12

5V. V. V. V. V. Equipment required:Equipment required:Equipment required:Equipment required:Equipment required:• Hanna HI 5315 Double Junction Re

Page 13

6VIIVIIVIIVIIVII. General GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral Guidelines• Calibration standards and sample solutio

Page 14

7HI 4011• Remove protective cover from sensor tip.• Prepare HI 5315 reference electrode by filling electro-lyte reservoir with HI 7072 fill solution.•

Page 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Page 16 - MAN4111 02/07R1

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and

Modèles reliés HI 4111

Commentaires sur ces manuels

Pas de commentaire