Hanna-instruments HI 4003 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI 4003. Hanna Instruments HI 4003 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
HI 4003HI 4003
HI 4003HI 4003
HI 4003
HI 4103HI 4103
HI 4103HI 4103
HI 4103
Instruction Manual
Half-cell
Combination
COMBINATION
CADMIUM
HI 4103
CADMIUM
HI 4003
Cadmium Ion
Selective Electrode
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Selective Electrode

1HI 4003HI 4003HI 4003HI 4003HI 4003HI 4103HI 4103HI 4103HI 4103HI 4103Instruction Manual Half-cell CombinationCOMBINATIONCADMIUMHI 4103CADMIUMH

Page 2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Page 3

11appear on polishing strip move the paper slightlyand continue polishing. • If the membrane is damaged, the response becomesextremely sluggish, or t

Page 4 - Membrane

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards / solution.Standards

Page 5

13This technique is called Known Addition. The method canuse an ideal sensor slope, but actual determined slopes atthe temperature of measurement sh

Page 6

14the free ions from the measurement pool.Cd2+ + EDTA <—>Cd-EDTAThe EDTA reacts with the cadmium ion forming a complex.The EDTA also can react w

Page 7

15XIV. SXIV. SXIV. SXIV. SXIV. Storage and Care of the HI 4003 andtorage and Care of the HI 4003 andtorage and Care of the HI 4003 andtorage and Care

Page 8 - Parafilm

16MAN4103 02/07 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warrante

Page 9 - COMBINATION

2HI 4003 Cadmium Half-cellHI 4003 Cadmium Half-cellHI 4003 Cadmium Half-cellHI 4003 Cadmium Half-cellHI 4003 Cadmium Half-cellHI 4103 Cadmium Co

Page 10

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4103 or HI 4103 c

Page 11

4IV. IV. IV. IV. IV. Design elements of the HI 4003 and HI 4103Design elements of the HI 4003 and HI 4103Design elements of the HI 4003 and HI 41

Page 12

5V. V. V. V. V. Equipment required:Equipment required:Equipment required:Equipment required:Equipment required:• Hanna HI 5315 Double Junction Re

Page 13 - ISA=1 mL

6VIIVIIVIIVIIVII. General GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral Guidelines• Concentrated samples (>0.10 M) shoul

Page 14

7• Gas bubbles may form from solution out-gassing dueto temperature change. Gently tap body of sensor todislodge them from sensing membrane.HI 4

Page 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Page 16 - MAN4103 02/07

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and

Modèles reliés HI 4103

Commentaires sur ces manuels

Pas de commentaire