Hanna-instruments HI8424 Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI8424. Hanna Instruments HI8424 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Instruction Manual
HI 8424
Portable pH/mV/°C Meter
www.hannainst.comMAN8424W R2 09/10
Printed in EUROPE
(ROMANIA)
Hanna Instruments Inc.
Highland Industrial Park
584 Park East Drive
Woonsocket, RI 02895 USA
Technical Support for
Customers
Tel. (800) 426 6287
Fax (401) 765 7575
Local Sales and Customer Service Office
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - Portable pH/mV/°C Meter

Instruction ManualHI 8424Portable pH/mV/°C Meterwww.hannainst.comMAN8424W R2 09/10Printed in EUROPE(ROMANIA)Hanna Instruments Inc.Highland Indust

Page 2

10• When the buffer value is recognized and thereading is stable, an acoustic signal (if en-abled) advises the user, the "pH" symbol stopsfl

Page 3

11• Rinse the temperature probe of a ChecktempC (or ChecktempF) or anotheraccurate thermometer, and place it close to the pH electrode.• Use the UP an

Page 4

12While in normal measurement mode, press and hold the CFM/SETUP key for about5 seconds until the meter enters the menu selection mode.The following p

Page 5 - SPECIFICATIONS

13HI 8424NEW has been accurately precalibrated for temperature at the factory.For optimum accuracy, it is recommended to recalibrate the meter for tem

Page 6 - OPERATIONAL GUIDE

14BATTERY REPLACEMENTBATTERY REPLACEMENTBATTERY REPLACEMENTBATTERY REPLACEMENTBATTERY REPLACEMENTThe meter displays the remaining battery per-centage

Page 7 - "S" VERSION

2Dear Customer,Thank you for choosing a HANNA instruments® product.Please read this instruction manual carefully before using the instrument.This manu

Page 8

3Remove the instrument from the packing material and examine it carefully tomake sure that no damage has occurred during shipment. If there is anydama

Page 9 - S = SCREW-TYPE CONNECTOR

41) BNC connector for pH or ORP electrodes2) Liquid Crystal Display (LCD)3) RANGE key, to select pH, mV or temperature range4) Up Arrow key, to manual

Page 10 - ACCESSORIES

5SPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSRange -2.00 to 16.00 pH±699.9 mV / ±1999 mV-20.0 to 120.0°C / -4.0 to 248.0°FRe

Page 11 - Oil/grease

6INITIAL PREPARATION• Remove the electrode protective cap before taking any measurements. If theelectrode has been left dry, soak the tip in HI 70300

Page 12

7TEMPERATURE COMPENSATIONThe meter is designed to compensate for temperature, as the response of the pHelectrode is directly affected by temperature.A

Page 13

8Notes:• To perform correct ORP measurements, the surface of the ORP electrode mustbe clean and smooth.• When not in use, the tip of the electrode sho

Page 14

9pppppH CALIBRATIONH CALIBRATIONH CALIBRATIONH CALIBRATIONH CALIBRATIONFor better accuracy, frequent calibration of the instrument is recommended.The