Hanna-instruments HI 84181 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI 84181. Hanna Instruments HI 84181 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
Instruction Manual
HI 84181
ISE Potassium
Meter
www.hannainst.com
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - HI 84181

1Instruction ManualHI 84181ISE PotassiumMeterwww.hannainst.com

Page 2 - WARRA (NTY

10Setup screensStability criteriaOptions: Accurate, Medium, Fast.Press the corresponding functional key to select the desired option.Select Accura

Page 3 - GENERAL DESCRIPTION

11Time formatOptions: AM/PM or 24 hours.Press the functional key in order to change the time format.Date/Time modify screenPress / to select the valu

Page 4

12LanguageOptions: Up to four languagesThis option is used to change the instrument’s display language.Press the corresponding functional key in orde

Page 5 - SPECIFICATIONS

13Displays the list of all the memorised results. This listincludes the record’s number, the concentration value, theconcentration unit and the date.P

Page 6 - FUNCTIONAL DESCRIPTION

14MEASUREMENT PROCEDURE• Fill the beaker up to the 50 mL mark with sample.Use the 2000 µL automatic pipette to add 2 mL ofHI 84181-0 ISA, place the st

Page 7 - START UP

15Notes:• If the reading is out of range, the upper range value isdisplayed blinking.• If the evaluated slope is out of 30-140 % range theinstrument d

Page 8 - GUIDE TO DISPLAY CODES

16PREPARATION PROCEDUREPreparation of potassium electrode:• Remove the protective cap from the HI 61014 potassium sensor’s tip.• Screw the potassium c

Page 9

17CLEANING PROCEDURE• Rinse the potassium electrode with deionised water. Check to see if the small scratches havebeen eliminated.• Soak the potassium

Page 10 - Setup screens

18PERIODIC MAINTENANCEInspect the electrode and the cable. The cable used for connection to the instrument must beintact and there must be no points o

Page 11

19REAGENTSHI 7076 Electrode filling solutionHI 84181-20 Reagent set for 20 testsHI 84181-0 ISA for Potassium electrode (500 mL)HI 84181-1 Standard 1 f

Page 12

2All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of thecopyright owner, Hanna Instruments Inc., Wo

Page 13 - Recall screens

20SALES AND TECHNICAL SERVICE CONTACTSSALES AND TECHNICAL SERVICE CONTACTSSALES AND TECHNICAL SERVICE CONTACTSSALES AND TECHNICAL SERVICE CONTACTSSALE

Page 14 - MEASUREMENT PROCEDURE

3PRELIMINARY EXAMINATIONPlease examine this product carefully. Make sure that the instrument is not damaged. If anydamage occured during shipment, ple

Page 15

4SIGNIFICANCE OF USEPotassium ion (K+) is absorbed in vine from earth. Unlike other essential nutrients potassiumremains in ionic form and passes to t

Page 16 - FUSE REPLACEMENT

5PRINCIPLE OF OPERATIONThe determination of potassium concentration is made according to double standard addition method.This technique enables an unk

Page 17

6REAR PANEL5) Potassium half cell 10) Temperature probe socket6) Reference half cell 11) BNC electrode connector7) Temperature probe 12) Power swit

Page 18

7KEYPAD DESCRIPTION1) ESC - to leave the current screen and to return either to the previous screen or to the main screen. In the setup paramete

Page 19 - WARRANTY

8When the input reading is unstable.When the stirrer is on.Temperature warning (only if the “Temperature compensation” is disabled). Thewarning symbol

Page 20 - MAN84181

9Result screenThe ion concentration is displayed in g/L (ppt) K+. If theconcentration is out of range, the instrument displays the upperrange limit bl

Commentaires sur ces manuels

Pas de commentaire