Hanna-instruments HI 95771 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI 95771. Hanna Instruments HI 95771 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
www.hannainst.com
This Instrument is in
Compliance with the CE Directives
Instruction Manual
HI 95771C
Chlorine
Ultra High Range
ISM
MAN95771CR3 06/06
www.hannainst.com
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Ultra High Range

www.hannainst.comThis Instrument is inCompliance with the CE DirectivesInstruction ManualHI 95771CChlorineUltra High Range ISMMAN95771CR3 06/06www.h

Page 2 - USER NOTES

10The blinking "BAT" indicates that the battery voltage is gettinglow and the battery needs to be replaced.This indicates that the battery i

Page 3 - CE DECLARATION OF CONFORMITY

11ERROR MESSAGESa) on zero readingThis indicates that the zeroing procedure failed due to a low signal-to-noise ratio. In this case press ZERO again.

Page 4 - ACCESSORIES

12The instructions listed below should be carefully followed during testing to ensure best accuracy.• For a correct filling of the cuvet: the liquid i

Page 5 - SPECIFICATIONS

2PRELIMINARY EXAMINATION ... 3GENERAL DESCRIPTION...

Page 6 - CALIBRATION PROCEDURE

3Please examine this product carefully. Make sure that the instrument is not damaged. If any damageoccured during shipment, please notify your Dealer.

Page 7

4The HI 95771 is an auto diagnostic portable microprocessor meter that benefits from Hanna’syears of experience as a manufacturer of analytical instru

Page 8 - VALIDATION PROCEDURE

5for 771 Chlorine ULTRA HIGH RANGERange 0 to 500 mg/LResolution 1 mg/L from 0 to 200 mg/L; 10 mg/L above 200 mg/LPrecision ±2 mg/L @ 100 mg/LTypical E

Page 9 - GUIDE TO DISPLAY CODES

6PRINCIPLE OF OPERATIONPrecision is how closely repeatedmeasurements agree with each other. Precisionis usually expressed as standard deviation (SD).A

Page 10

7Photometric chemical analysis is based on the possibility to develop an absorbing compound from aspecific chemical reaction between sample and reagen

Page 11 - MEASUREMENT PROCEDURE

81) Liquid Crystal Display2) Cuvet Holder3) Cuvet alignment indicator4) ON/OFF key5) ZERO/SET key6) READ/TIMER key7) CAL CHECK keyFUNCTIONAL DESCRIPTI

Page 12 - OPERATIONAL GUIDE

9DISPLAY ELEMENTS DESCRIPTION1) four digit main display area.2) CAL: appears when the instrument operates in the calibration mode.3) the Month and Day