Hanna-instruments HI 93501 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hanna-instruments HI 93501. Hanna Instruments HI 93501 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
Instruction Manual
HI 9241
HI 93501
HI 93501S
HI 93503
HI 935007
Portable Microprocessor
Thermometers
www.hannainst.com
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - HI 935007

1Instruction ManualHI 9241HI 93501HI 93501SHI 93503HI 935007Portable MicroprocessorThermometerswww.hannainst.com

Page 2

10WARNING MESSAGESNO PROBE messageIf the probe is not connected “NOPROBE” message is displayed.DAMAGED PROBE messageWhen the readings are very far fro

Page 3 - GENERAL DESCRIPTION

11When the remaining battery life is less than 10% the battery tagblinks on the display to warn the user.If the battery level is low enough to causeer

Page 4 - SPECIFICATIONS OF HI 9241

12Hanna offers a wide range of probes to meet your needs with air,liquid, penetration and surface measurements.All Hanna temperature probes are pre-ca

Page 5 - Main features:

13HI 762PWL Penetration probe w/1 m (3.3') cable & whitehandleHI 762W Wire probe without handle for hard-to-reachplaces w/1 m (3.3') cab

Page 6 - SPECIFICATIONS OF HI 93503

14places w/10 m (33') cableFOR HI 935007HI 766C (*) Penetration, K-type thermocouple probe w/1 m(3.3') cable (*) To be replaced only by auth

Page 7 - SPECIFICATIONS OF HI 935007

15Hanna Instruments reserves the right to modify the design,construction and appearance of its products without advance notice.RECOMMENDATIONS FOR USE

Page 8 - OPERATIONAL GUIDE

16Printed in EUROPE(ROMANIA)MAN93501Y 10/10Hanna Instruments Inc.Highland Industrial Park584 Park East DriveWoonsocket, RI 02895 USATechnical Suppor

Page 9 - CALIBRATION CHECK

2Dear Customer,Thank you for choosing a Hanna product.Please read this instruction manual carefully before using the instrument.This manual will provi

Page 10 - DAMAGED PROBE message

3Remove the instrument from the packing material and examine it tomake sure that no damage has occurred during shipping. If there isany damage, notify

Page 11 - BATTERY REPLACEMENT

4Main features:• HI 765 probes series• Calibration Check feature• Remaining battery life indication / low battery detection• Auto-off capability• Wate

Page 12 - TEMPERATURE PROBES

5Main features:• HI 762 probes series• Range -50 to 150 °C• Calibration Check feature• Remaining battery life indication / low battery detection• Stab

Page 13 - FOR HI 9241 AND HI 93503

6Main features:• HI 765 probes series• Range -50 to 150 °C• Calibration Check feature• Remaining battery life indication / low battery detection• Stab

Page 14 - FOR HI 935007

7Main features:• Direct HI 766C K-thermocouple probe• Available in °C• Range -50.0 to 1350 °C• Remaining battery life indication / low battery detecti

Page 15

8Each meter is supplied with batteries. Remove the battery cap, un-wrap the supplied batteries and install them while paying attention totheir polarit

Page 16 - MAN93501Y 10/10

9CALIBRATION CHECKAll the models are provided with auto-matic Cal-Check feature at start-up, whichallows the user to check the instrumentcalibration s