Instruction Manual
www.hannainst.com
Dear Customer,
Thank you for choosing a Hanna Product.
Please read the instruction sheet carefully before using the
test kit. It will provide you with the necessary information
for correct use of the kit. If you need additional information,
do not hesitate to e-mail us at [email protected].
Remove the chemical test kit from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable dam-
age, notify your Dealer or the nearest Hanna office
immediately.
Each kit is supplied with:
HI 38083A-0 Calcium Sulfate, 1 bottle (10 g);
Buffer Solution 10.2±0.2, 1 bottle with dropper
(30 mL);
HI 38083C-0 EDTA Solution, 3 bottles (3 x 100 mL);
Calmagite Indicator, 1 bottle with dropper (10 mL);
Demineralizer Bottle with filter cap for about 12 liters
of deionized water (depending on the hardness level
of water to be treated)
;
1 2-mm soil sieve;
1 plastic test tube (14 mL) with screw cap;
1 plastic test tube (50 mL) with screw cap;
1 small funnel;
filter paper discs
80 mm (100 pcs);
1 brush;
1 calibrated plastic vessel (50 mL);
ISTR38083 02/00 PRINTED IN ITALY
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONS
SAMPLING PROCEDURESAMPLING PROCEDURE
SAMPLING PROCEDURESAMPLING PROCEDURE
SAMPLING PROCEDURE
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USE
Alkaline soils are characterized by a low electrical conductiv-
ity (EC), high exchangeable sodium percentage (ESP) and
presence of carbonate and bicarbonate sodium salts. Hy-
drolysis of carbonate causes also an increase in pH, such
that it is always greater than 8.5.
The "saline-sodic" soil group, which possesses the following
peculiarities, also belongs to this alkaline group:
EC > 4 mmhos, ESP > 15, pH 8.5
High alkalinity causes impairment to plant growth since it
gives rise to an incomplete solubilization of necessary nutri-
ents such as iron, copper and manganese. Chlorosis, for
instance, is a typical disease of leaves due to iron deficiency.
It is possible to correct soil alkalinity by adding a proper
compound (generally gypsum) that removes sodium and
decreases the pH. The exact quantity of gypsum needed for
correction can be calculated with the Hanna Gypsum Re-
quirement Test Kit.
READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT
Remove the cap and fill
the Demineralizer Bottle
with tap water.
Replace the cap
and shake gen-
tly for at least
2 minutes. The
demineralized
water is now
ready.
Flip open the top of the Dem-
ineralizer Bottle cap. By gently
squeezing the bottle, add dem-
ineralized water to the large (50
mL) test tube up to the 25 mL
mark.
Add 1 spoon of HI 38083A-0 Calcium Sulfate (discard
the excess soil by using the handle of the other spoon).
Place the cap
on the tube
and shake it
several times
during a 15
minute period.
Place the tube into the
large (50 mL) vessel and
wait for 30 minutes. The
saturated calcium sulfate
extractant solution is
ready.
2 calibrated plastic vessels (20 mL) with cap;
1 plastic pipette (3 mL);
1 plastic pipette (1 mL);
1 syringe (1 mL) with tip;
2 spoons.
Note: Any damaged or defective item must be returned in
its original packing materials.
WHEN TO TEST YOUR SOIL
Soil should be tested not only when the plant appears to
be unhealthy (yellow leaves or stunted growth), but prior to
seeding, planting and fertilizing as well as when other
material such as manure or compost has been added.
SAMPLING
1) Soil Sample Extraction
Within a large homogeneous area, take 1 or 2 samples
per 1000 m
2
(0.25 acre).
Even for smaller areas, 2 samples are recommended
(the more samples, the better the end-results, be-
cause the end sample is more representative).
For a small garden or plot, 1 sample is sufficient.
2) Avoid extracting samples from soil presenting obvious
anomalies and from border areas (near ditches and roads).
3) Sample quantity:
Take the same quantity of soil for each sample. For ex-
ample, use bags with similar dimensions (1 bag per
sample).
4) Depth of extraction:
General: dig and discard 5 cm (2") of topsoil
For lawns: take the sample at a depth of 5 to 15 cm (from
2" to 6").
For other plants (flowers, vegetables, shrubs): from 20 to
40 cm of depth (8" to 16").
For trees: Samples from 20 to 60 cm of depth (8" to 24'’).
5) Mix all the samples together to obtain a homogeneous
mixture of soil, discarding stones and vegetable residues.
6) From this mixture, take the quantity of soil that you
need for the analysis.
7) Crumble the large chunks and distribute the soil sample
on paper or plastic to air dry it.
8) Use a small bar to crush the air dried sample and pass it
through the 2-mm soil sieve.
Range GR: 0 to 213 metric ton/ha
(0 to 95 ton/acre)
EES: 0 to 56.4 meq/100 g soil
Smallest Increment 3.8 metric ton/ha (1.7 ton/acre) as GR
1.95 meq/100 g soil as EES
Analysis Method Drop count titration
Sample Size 0.5 mL of soil
Number of Tests 100
Case Dimensions 235x175x115 mm (9.2x6.9x4.5")
Shipping Weight 883 g (31.1 oz.)
Note: GR is Gypsum Requirement and EES is Estimated Exchange-
able Sodium; meq/100 g is milliequivalent per 100 grams.
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
25 mL
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTION
The extraction method is the saturated calcium sulfate method.
The Hanna Test Kit determines Gypsum Requirement by
titration of Calcium. The indicator chelates with Calcium ions
to form a red colored complex. As EDTA is added, calcium
complexes with it: the reaction endpoint is indicated by a
change in color of the indicator from red to blue.
HI 38083
Gypsum Requirement
&
Exchangeable Sodium
Test Kit
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Instruction Manual

Instruction Manualwww.hannainst.comDear Customer,Thank you for choosing a Hanna Product.Please read the instruction sheet carefully before using thet

Page 2

The chemicals contained in this kit may be hazardous ifimproperly handled. Read the relevant Health and SafetyData Sheet before performing this test.H

Commentaires sur ces manuels